Ignore:
Timestamp:
Jul 20, 2017 3:22:34 PM (5 years ago)
Author:
srkline
Message:

LOTS of changes to accommodate the beam center being reported in cm rather than pixels. Required a lot of changes to VCALC (to fill in simulated data), and in the reading and interpreting of data for display, and most importantly, the calculation of q.

There may still be a few residual bugs with this. I am still re-testing with new sample data sets.

File:
1 edited

Legend:

Unmodified
Added
Removed
  • sans/Dev/trunk/NCNR_User_Procedures/Reduction/VSANS/V_Correct.ipf

    r1024 r1055  
    317317                 
    318318        // to check for beam center mismatch -- simply warn, but do no shift 
    319         // 
     319        // NOTE - these are now reading the beam center in cm, not pixels 
    320320 
    321321                csam = V_getDet_beam_center_x("SAM",detStr)             //x center 
Note: See TracChangeset for help on using the changeset viewer.