Ignore:
Timestamp:
Sep 18, 2017 12:08:50 PM (5 years ago)
Author:
srkline
Message:

many minor changes after real VSANS data collected.

additional procedures added to allow easy correction of the incorrect header information from NICE.

Most notable addition is the pinhole resolution added to the calculation and the I(q) output. White beam is also treated (incorrectly) as a gaussian distrivution, but the results of smeared fitting look to be quite good.

Trimming and sorting routines are now (pinhole) resolution aware.

File identification routines have been updated to use the proper definitions of "purpose" and "intent". Both fields are now in the catalog, to allow for better sorting.

File:
1 edited

Legend:

Unmodified
Added
Removed
  • sans/Dev/trunk/NCNR_User_Procedures/Reduction/VSANS/V_MaskUtils.ipf

    r1050 r1064  
    573573        SetScale/P y 0,1, curDispPanel 
    574574         
     575        Wave LookupWave = root:Packages:NIST:VSANS:Globals:logLookupWave 
     576 
    575577        //draw the detector panel 
    576578        Display/W=(left,top,right,bottom)/HOST=#  
    577579        AppendImage curDispPanel 
    578580        ModifyImage curDispPanel ctab= {*,*,ColdWarm,0} 
     581//      ModifyImage curDispPanel log=1          // this fails, since there are data values that are zero 
     582        ModifyImage curDispPanel ctabAutoscale=0,lookup= LookupWave 
    579583        Label left "Y pixels" 
    580584        Label bottom "X pixels"  
Note: See TracChangeset for help on using the changeset viewer.