Ignore:
Timestamp:
Apr 5, 2019 3:11:26 PM (4 years ago)
Author:
srkline
Message:

updates to the beam center corrections that take into account the lateral variation of zero points of the tubes. This is an important correction to the reference beam center, especially when the graphite monochrmoator is used.

various bug fixes included as part of reduction , largely to catch missing or incorrect information in the file header.

New "patch" functions have been added for number of guides, beam stops, source aperture, etc. which were missing in the file and caused the resolution calculation to be totally incorrect.

File:
1 edited

Legend:

Unmodified
Added
Removed
  • sans/Dev/trunk/NCNR_User_Procedures/Reduction/VSANS/V_Protocol_Reduction.ipf

    r1122 r1141  
    25432543                                        tmpReadNoiseLevel_Err = kReadNoiseLevel_Err_bin1                // a constant value 
    25442544                                         
    2545                                         MatrixFilter /N=11 /P=1 median w                        //              /P=n flag sets the number of passes (default is 1 pass) 
    2546                                          
    2547                                         Print "*** median noise filter 11x11 applied to the back detector (1 pass) ***" 
     2545//                                      MatrixFilter /N=11 /P=1 median w                        //              /P=n flag sets the number of passes (default is 1 pass)                          
     2546//                                      Print "*** median noise filter 11x11 applied to the back detector (1 pass) ***" 
     2547                                        Print "*** 1x1 binning, NO FIlTER ***" 
    25482548                                        break 
    25492549                                case 4: 
     
    25512551                                        tmpReadNoiseLevel_Err = kReadNoiseLevel_Err_bin4                // a constant value 
    25522552                                                                         
    2553                                         MatrixFilter /N=3 /P=3 median w                 //              /P=n flag sets the number of passes (default is 1 pass) 
     2553//                                      MatrixFilter /N=3 /P=3 median w                 //              /P=n flag sets the number of passes (default is 1 pass) 
    25542554                                         
    2555                                         Print "*** median noise filter 3x3 applied to the back detector (3 passes) ***" 
     2555//                                      Print "*** median noise filter 3x3 applied to the back detector (3 passes) ***" 
     2556                                        Print "*** 4x4 binning, NO FIlTER ***" 
     2557 
    25562558                                        break 
    25572559                                default: 
Note: See TracChangeset for help on using the changeset viewer.