Ignore:
Timestamp:
Jul 6, 2012 5:29:38 PM (10 years ago)
Author:
srkline
Message:

Added support for reading 4-column data into the 2D reader

Calculation of kappa for ABS now does a specific byte check for ensuring a "good" DIV file. hopefully this will eliminate errors where incorrect DIV files are selected and bad kappa values are generated - and the program thinks (incorrectly) that there is a valid DVI file present, when there really isn't one (and then there is no easy recovery from this)

Added CheckIfDIVData() functions to NCNR_Utils and to FACILITY_Utils, and to other (facility)_Utils

Changed the calls to writing BT5 files after adding so that it could be more easily scripted in the future.

File:
1 edited

Legend:

Unmodified
Added
Removed
  • sans/Dev/trunk/NCNR_User_Procedures/Reduction/SANS/ProtocolAsPanel.ipf

    r853 r857  
    21092109                        endif 
    21102110#else 
    2111                         if(strlen(junkStr)==0 || CheckIfRawData(junkStr))               //for NCNR, not raw is sufficient, but better in the future to confirm it is DIV if either is false, exit 
     2111                        if(strlen(junkStr)==0 || !CheckIfDIVData(junkStr))              //for NCNR, and other data confirm it is DIV if either is false, exit 
    21122112                                SetDataFolder root: 
    21132113                                Abort "No DIV (PLEX) file selected. Please use setABSParams again, selecting the empty beam file and then the detector sensitivity (Plex_) file" 