Release notes for version 7.98:
- DIV file generation now fully supports the HighRes? detector.
- Fixed compile errors due to missing XML xop.
- Added patch for updating the XY pixel dimensions of the HighRes? detector.
Release notes for version 7.97:
- Bug fix for % sign printing in Igor 8.
- Additional support for super white beam mode on VSANS.
- Corrected display of images in VSANS Help file.
- Corrected display of temperature sensor graph in VSANS.
Release notes for version 7.96:
- Significant update to QUOKKA SANS macros.
- Minor changes to SANS and VSANS.
Release notes for version 7.95:
- Attenuator tables for VSANS have been updated to cover the wavelength range 4.52 Å to 19 Å.
- Attenuator tables for NGB 30m SANS have been updated to include 3 Å.
- Help file for VSANS is now integrated within the macros (but not yet completely written).
Release notes for version 7.94:
- Binning of data in larger q-bins during reduction can now be set as a preference. Non-integer bins are allowed.
- Recalling a protocol now properly fills in all of the global values, including number of points trimmed.
- DIV files are now generated by normalizing all 8 middle + front panels simultaneously.
- Smoothed USANS data sets can now be saved directly from the desmearing panel.
Release notes for version 7.93:
- QxQy? ASCII export now includes a 9th column containing the mask, and has the .DAT extension
- The averaging option "Yes - Individual" will save each detector panel as an individual file without concatenation
- Detector sensitivity files (DIV) can now be generated for the High-Res detector
Release notes for version 7.92:
- sensor data (temperature) can now be plotted if it is present
- sector averaging now uses the same angle definitions as for SANS
Release notes for version 7.91:
- updated beam center calculations with improved accuracy
Release notes for version 7.90:
- corrected the handling of new NICE-generated USANS data
Release notes for version 7.89:
- Support for the new (NICE-generated) USANS data format of q-values rather than angle is included.
- VCALC has been improved greatly to allow easier configuration of the VSANS instrument, including hard/soft shadowing of the detector panels to calculate realistic q-ranges, more details of flux conditions, preset configurations to start from, and the ability to print out configurations.
- The Real Time display of VSANS data now works using the current VSANS data on charlotte.
Release notes for version 7.87 / 7.88:
- Support for the new (NICE-generated) USANS data format (swapped columns) is included
- Support for VSANS output format of QxQy? ASCII has been added
Last modified 2 years ago
Last modified on Apr 8, 2020 10:36:06 AM